Engineering Notes

Siemens PLC Market Share Leads—But 'Buy the Best-Seller' Logic Cost Me $3,200

Posted 2026-11-17 by Kwame Boateng

The surface problem I thought I was solving

When I first started specifying PLCs for integration projects, my logic was embarrassingly simple. Siemens is the global leader in PLC market share. Siemens PLCs are everywhere. Therefore, buy Siemens and you're safe.

Seven years, eleven documented mistakes, and roughly $3,200 in wasted budget later, I can tell you: that logic is correct—and completely insufficient.

The first time it cost me real money was September 2022. I quoted a control cabinet upgrade for a packaging line using an S7-1200. The design looked clean. The hardware arrived. Then we tried to commission it with the customer's existing TIA Portal install (V15.1). My project was built in V17. The firmware mismatch alone cost us four days and a $600 emergency support call.

But the version mismatch was just the visible symptom. The deeper issue—the one that took me years to internalize—is that a Siemens PLC is not a single product. It is the center of a gravity well made of software versions, firmware revisions, training assumptions, and system boundaries. If you don't respect those boundaries, the market leadership doesn't save you.

Why 'market share leader' masks the real risk

This is the logic I hear most often, because on paper it looks bulletproof. According to Omdia's 2024 analysis of 2023 PLC shipments, Siemens held roughly a third of the global PLC market. That's more than any competitor. When a category has a clear leader, the instinct is to pick it and move on.

The problem is that this instinct conflates market dominance with ecosystem fit. Market share tells you how many people bought a PLC. It doesn't tell you whether that PLC will work in your specific site, with your team's existing software version, or with the person actually holding the screwdriver.

This was my first oversimplification. I assumed PLCs were interchangeable at the brand level. It took me three years and about 40 projects to understand that selection accounts for maybe 10% of the work—the other 90% is ecosystem and boundary management.

The TIA Portal version maze

TIA Portal versions iterate faster than most teams can keep up with. Between V15 and V17, the instruction set changed, libraries shifted, and online diagnostics behaved differently. If a client's maintenance team is still on V15.1 and you build the project in V17, you are signing up for a compatibility project you didn't budget for.

That September 2022 project wasn't a one-off. It was the first time I paid attention to a structural trap.

The 'Udemy course is enough' illusion

There are decent Siemens PLC courses on Udemy. I've taken a couple myself. But a crash programming course teaches you what ladder logic looks like and how to declare a variable. It does not teach engineering judgment—when to use a timer versus a counter, what kind of shielding an analog signal needs, or why you shouldn't let a newly certified tech touch a live loop on their own.

A technician on my team—a smart guy, Udemy-certified in Siemens PLC programming—once called me because an analog input was reading erratic values. "How do you measure resistance with a multimeter?" he asked. I said, you disconnect the wire first. He had been measuring resistance across a live 4–20 mA loop. The meter was fine. The sensor was fried ($340, gone). The lesson had nothing to do with Siemens PLCs.

The all-in-one trap: PLCs as power management

This is the most expensive misconception, and it cuts to a specific boundary. Siemens PLCs are excellent at control logic, communication, and diagnostics. They are not power distribution equipment.

I once watched a team try to route backup power logic through an S7-300 because "the PLC already has an analog input for voltage monitoring." The circuit breaker panel board was in another room. The whole home transfer switch was manual. The PLC wasn't rated for the switching current. They burned out two output cards ($600) before agreeing that power management belongs to power equipment, not the controller.

A good supplier will tell you where that line is. I learned—slowly—that when a supplier says "this isn't our strength, here's who does it better," they earn more trust than the vendor who says yes to everything. That's exactly what happened with a local distributor who refused a project that belonged in the power distribution space, and pointed me to three specialists instead.

What the unaddressed problem actually cost

Here are the numbers I've gone back and reconciled.

September 2022: TIA Portal version mismatch, plus firmware upgrade and expedited support. Four days of delays. Direct cost: $600 support fee plus roughly $700 in line-down time.

Early 2023: Let a Udemy-trained tech commission a loop. Fried sensor ($340), plus recalibration of two adjacent channels and a partial line stop (~$760).

2024: The power management project. Two output cards ($600) and one day of delayed production (~$200).

That totals roughly $3,200—give or take a few hundred, I'd have to check the old ticket logs. But the number is not the point. The point is that every one of these was the same underlying mistake: assuming that Siemens PLC market share meant the product could handle anything, fit anywhere, and be learned by anyone.

Market share doesn't fix ecosystem boundaries. It's a market signal, not an engineering decision.

The short version of what I do now

I no longer specify a Siemens PLC without a short pre-quote checklist. It takes about 20 minutes and has caught at least 47 potential errors in the last 18 months.

  1. Confirm the customer's TIA Portal version and firmware level. Put it in the quote. This is the most obvious question and the one most often skipped.
  2. Confirm the team's skill level. Has anyone actually commissioned an analog loop? If the answer is "they took a Udemy course," pair them with someone who has.
  3. Write down what the PLC is not doing. Power distribution, circuit breaker panel boards, transfer switches—those belong to dedicated equipment. A Siemens PLC can monitor them; it should not switch them.
  4. Teach the multimeter basics before anyone touches hardware. Disconnect before measuring resistance. Always. Every hardware-adjacent mistake on a commissioning schedule traces back to this.

I've come to believe that the real value of a market-leading PLC is not that it does everything. It's that it does its specific job well enough that you have room to respect the line between what it does and what you shouldn't ask it to do.

Kwame Boateng

Kwame Boateng

Kwame Boateng is a transformer and power-conversion analyst specializing in distribution transformers, power supplies, inverters, and network integration. He uses IEC 60076 test data for transformer ratio, impedance, losses, and temperature rise, and IEC 62477-1 safety requirements for converter insulation and thermal boundaries while separately comparing harmonics and efficiency curves. He helps engineers and sourcing teams compare equipment against duty profiles, environmental limits, short-circuit behavior, lifecycle energy cost, and service requirements.